This is a software vulnerability notice, not a scam. Siemens Capital Embedded AR Classic has an out-of-bounds read flaw that could cause denial of service. Update to the latest version or apply network protections.
iLow iAuto-summarised
Auto-summarised from CISA cybersecurity advisories; a person reviews High and Critical items. Published 22 Oct 2026.
What it looks like
- Arrives by
- not stated
- Pretends to be
- not named
- Targets
- Businesses, all
Red flags
The source's notice
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded AR Classic are affected: Capital Embedded AR Classic 431-422 vers:all/* (CVE-2026-89208) Capital Embedded AR Classic R20-11 vers:intdot/<2303 (CVE-2026-89208) CVSS Vendor Equipment v3 5.3 Siemens Capital Embedded AR Classic 431-422 1 Vulnerability Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-89208 The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries. Read More 2 Affected Products Capital Embedded AR Classic 431-422 Product Status: known_affected Remediations MitigationApply network segmentation and put the ECUs behind properly configured gateways/firewalls No fix plannedCurrently no fix is planned Capital Embedded AR Classic R20-11 < V2303 Product Status: known_affected Remediations MitigationApply network segmentation and put the ECUs behind properly configured gateways/firewalls Vendor fixUpdate to V2303 or later version Additional Metrics Relevant CWE: CWE-125 Out-of-bounds Read CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals…
Common questions
Who does this scam pretend to be?
The notice does not name a specific organisation.
How does it reach you?
The notice does not say which channel.
What should I do if I already responded?
Call your bank on the number on your card, change the password you used and turn on two-factor sign-in, then report it (links below).